2

Connector Assignments and Functions

 

 

Multi-function X40

2.5.1Incremental Output

EASYRIDERWindows - Software X40 Mode = 0

Incremental encoder simulation for processing in positioning modules Standard: 1024 increments

pulse duty cycle

further selectable pulse numbers: 2048, 512, 256, 128, 64, 4096

Inr. I/O X40

 

PIN

 

 

Function

 

 

Designation

 

 

 

X40

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Channel B

B

 

2

 

Channel B inverted

/B

 

3

 

 

Shield connector

Shield

 

4

 

Channel A

A

 

5

 

Channel A inverted

/A

 

6

 

 

Reference *

 

GND

 

7

 

 

Channel Z inverted zero impulse

 

/Z

 

8

 

 

Channel Z, zero impulse

 

Z

 

9

 

Supply voltage output max. 150 mA

 

+ 5 VDC

 

Design Rule:

The input frequency range of the connected control must meet at least the value of pulse output frequency on X40.

n = max. speed (rpm)

x = increments e.g. 1024

f = output frequency at X40.1,2,4,5

Formula: f = 1,2 * (n * x) = [Hz] 60

Example: n = 4000 1/min

f= 1,2 * (4000 *1024) = 81920 Hz 60

2.5.2Incremental-Input

EASYRIDERWindows - Software X40 Mode = 1

Parameter range of the input signals: 10...1000000 increments

Figure:

Note:

The operation of incremental encoders via long cables may cause a voltage drop of the encoder power supply. We recommend the use of a separate voltage supply if necessary.

________________________________________________________________________________________________________________________________________________________________________________________________________________________

32

Product Manual Type: 637f

07-02-10-01-E-V0505.doc