Connector Assignments and Functions

2

 

 

2.5Multi-function X40

Description of the X40:

Via a programmable I/O processor, the X40 connection can be configured differently. EASYRIDERWindows - Software

Standard functions:

-Incremental output

-Incremental input

-Stepper motor - pulse inputs

-SSI interface

The unobstructed configurability provides ideal conditions for synchronous applications.

General data

 

X40

plug type:

SUB D 09 male plug

maximum input or output frequency:

200 kHz

 

maximum cable length connected to galvanical

25 m; for extended distances please contact our

insulated terminals

engineer

(Encoder, controls)

 

 

maximum cable length connected to ground-

2 m, take care for good common grounding !

related terminals (other drives, controls)

 

 

maximum number of signal inputs to one as

8

 

incremental-output configured device

 

 

output signals:

driver model MAX483 or compatible, RS422

differential logic level:

L 0,5V

H 2,5V

nominal range:

0,0 ... 5,0V

150mA max.

input signals:

receiver model MAX483 or compatible, RS422

differential input level:

diff min = 0,2V

 

nominal signal difference:

1,0V

 

current consumption:

1...4 mA (depending on frequency)

Notice:

Master / Slave operation

1 Master, maximum 8 Slaves Condition: Devices directly side by side !

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

31