2 | Connector Assignments and Functions |
|
|
Signal Connections
Control Signal Plug X10 - SUB D25 Socket
Inputs / Outputs
Control Signal Plug X10
| PIN |
|
| function |
|
| type |
|
| description |
|
|
| X10 |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||||||
1 |
|
| shield connector |
|
|
| shield |
| ||||
2 |
|
| configurable (chapter 3) | OPTO | input |
| ||||||
3 |
|
| stabilized auxiliary voltage |
|
|
|
| output auxiliary voltage |
| |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ||
4 |
|
| configurable (chapter 3) | OPTO | input |
| ||||||
5 |
|
| reference point to X10.18 |
|
|
|
| analog input |
| |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| Ri = 10 kOhm |
| |
6 |
|
| Current monitor can be scaled |
|
|
|
| MP2 analog output, |
| |||
|
| in the speed controller menu |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
| via JP100 (solder jumper) |
|
|
|
| Optional |
| ||
7 |
|
| can be assigned as free and |
|
|
|
|
|
|
| ||
|
| loopable potential of the |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| READY contact |
|
|
|
|
|
|
| |
|
|
|
| ON: regulator without fault |
| Relay | Output |
| ||||
8 |
|
| OUT: regulator fault or |
|
|
|
| fixed: ready |
| |||
|
|
|
| supply voltage off |
|
|
|
|
|
|
| |
9 |
|
| Reference point for digital |
|
|
|
| Reference point for digital inputs |
| |||
|
| inputs |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
10 |
|
| Reference potential for |
|
|
|
| Ground |
| |||
|
| analog signals |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
11 |
| configurable (chapter 3) | OPTO | Input |
| |||||||
12 |
| configurable (chapter 3) | OPTO | Output |
| |||||||
13 |
|
| configurable (chapter 3) | OPTO | Output |
| ||||||
14 |
|
| configurable (chapter 3) | OPTO | Input |
| ||||||
15 |
| configurable (chapter 3) | OPTO | Input |
| |||||||
16 |
|
| stabilized auxiliary voltage |
|
|
|
| output auxiliary voltage |
| |||
|
| +12V DC; max 80 mA |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
17 |
|
| actual speed value monitor, |
|
|
|
| MP1 analog output, |
| |||
|
| scalable |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
| nominal speed value; |
|
|
|
| Analog input |
| ||
18 |
|
| scalable differential |
|
|
|
|
| ||||
|
|
|
| referenced to X10.5 |
|
|
|
|
|
|
| |
|
|
|
| Setting of the current limit |
|
|
|
| analog input |
| ||
19 |
|
| can be activated and scaled |
|
|
|
| 0..+10V |
| |||
|
|
|
| (0..+10V for 0.. Imax) |
|
|
|
| Ri = 10 kOhm |
| ||
20 |
| configurable (chapter 3) | OPTO | Output |
| |||||||
21 |
| Nominal: 24V DC |
|
|
| Supply for outputs |
| |||||
22 |
|
| H = output stage is active | OPTO |
| input |
| |||||
|
| L = output stage inactive |
|
|
|
| fixed: active |
| ||||
|
|
|
|
|
|
|
|
| ||||
23 |
|
| configurable (chapter 3) | Relay | output |
| ||||||
24 |
| configurable (chapter 3) | OPTO | input |
| |||||||
25 |
| configurable (chapter 3) | OPTO | input |
|
Data of the digital inputs and outputs see chapter 11 General technical data
Reference to Pin 22 & Pin 23: With controllers with option module SBT, kindly note the extended functions of these signals (see documentation
________________________________________________________________________________________________________________________________________________________________________________________________________________________
28 | Product Manual Type: 637f |