2

Connector Assignments and Functions

 

 

Signal Connections

Control Signal Plug X10 - SUB D25 Socket

Inputs / Outputs

Control Signal Plug X10

 

PIN

 

 

function

 

 

type

 

 

description

 

 

 

X10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

shield connector

 

 

 

shield

 

2

 

 

configurable (chapter 3)

OPTO

input

 

3

 

 

stabilized auxiliary voltage

 

 

 

 

output auxiliary voltage

 

 

 

-12VDC; max. 80 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

configurable (chapter 3)

OPTO

input

 

5

 

 

reference point to X10.18

 

 

 

 

analog input

 

 

 

 

 

 

 

 

 

0...+-10V

 

 

 

 

 

 

 

 

 

 

 

Ri = 10 kOhm

 

6

 

 

Current monitor can be scaled

 

 

 

 

MP2 analog output,

 

 

 

in the speed controller menu

 

 

 

 

0…+-10V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

via JP100 (solder jumper)

 

 

 

 

Optional

 

7

 

 

can be assigned as free and

 

 

 

 

 

 

 

 

 

loopable potential of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READY contact

 

 

 

 

 

 

 

 

 

 

 

ON: regulator without fault

 

Relay

Output

 

8

 

 

OUT: regulator fault or

 

 

 

 

fixed: ready

 

 

 

 

 

supply voltage off

 

 

 

 

 

 

 

9

 

 

Reference point for digital

 

 

 

 

Reference point for digital inputs

 

 

 

inputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

Reference potential for

 

 

 

 

Ground

 

 

 

analog signals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

configurable (chapter 3)

OPTO

Input

 

12

 

configurable (chapter 3)

OPTO

Output

 

13

 

 

configurable (chapter 3)

OPTO

Output

 

14

 

 

configurable (chapter 3)

OPTO

Input

 

15

 

configurable (chapter 3)

OPTO

Input

 

16

 

 

stabilized auxiliary voltage

 

 

 

 

output auxiliary voltage

 

 

 

+12V DC; max 80 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

actual speed value monitor,

 

 

 

 

MP1 analog output,

 

 

 

scalable

 

 

 

 

0…+-10V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

nominal speed value;

 

 

 

 

Analog input

 

18

 

 

scalable differential

 

 

 

 

0...+-10V / Ri = 10 kOhm

 

 

 

 

 

referenced to X10.5

 

 

 

 

 

 

 

 

 

 

 

Setting of the current limit

 

 

 

 

analog input

 

19

 

 

can be activated and scaled

 

 

 

 

0..+10V

 

 

 

 

 

(0..+10V for 0.. Imax)

 

 

 

 

Ri = 10 kOhm

 

20

 

configurable (chapter 3)

OPTO

Output

 

21

 

Nominal: 24V DC

 

 

 

Supply for outputs

 

22

 

 

H = output stage is active

OPTO

 

input

 

 

 

L = output stage inactive

 

 

 

 

fixed: active

 

 

 

 

 

 

 

 

 

 

23

 

 

configurable (chapter 3)

Relay

output

 

24

 

configurable (chapter 3)

OPTO

input

 

25

 

configurable (chapter 3)

OPTO

input

 

Data of the digital inputs and outputs see chapter 11 General technical data

Reference to Pin 22 & Pin 23: With controllers with option module SBT, kindly note the extended functions of these signals (see documentation 07-02-10-02-E-Vxxxx).