2

Connector Assignments and Functions

 

 

Digital Interfaces

2.6.2Fieldbus Interface - COM2

Option modules SUB D09 socket

Many different functions can be implemented by optional using of the option modules. Funktionen realisiert werden. Layout - see chapter 1.2.3

Overview:

module designation

 

interface

 

galvanic isolation

design

slot

RP 232

 

RS 232

 

 

-

 

A

A

 

 

 

 

 

 

 

 

 

 

RP 422

1)

RS 422/485

 

 

-

 

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RP 485

1)

RS 422/485

 

 

X

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

RP CAN

 

CAN

 

 

X

A

A

 

 

 

 

 

 

 

 

 

 

RP PDP

 

Profibus DP

 

 

X

B

B

 

 

 

 

 

 

 

 

 

 

RP SUC

 

SUCOnet K

 

 

X

B

B

 

 

 

 

 

 

 

 

 

 

RP IBS

2)

Interbus S

 

 

X

B

B

 

 

 

 

 

 

 

 

 

 

 

 

 

RP DEV

 

DeviceNet

 

 

X

B

B

 

 

 

 

 

 

 

 

 

 

RP 2CA

3)

CAN1/CAN2

 

 

X

B

B or C

 

 

 

 

 

 

 

 

 

 

 

 

 

RP 2C8

3)

CAN1/CAN2

 

 

X

B

B or C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) full - duplex (4-wire)

 

 

 

 

 

 

 

2) additional plug Interbus Rem. IN (SUB D)

 

 

 

3) additional plug COM 3 (B)

 

 

 

 

2.6.2.1 additional In-/Outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

module designation

 

inputs

 

outputs

connection via

 

design

slot

RP EA5

4)

5

 

2

COM2

 

B

B

 

 

 

 

 

 

 

 

 

 

 

 

RP EAE

 

14

 

10

X200

 

C

C

 

 

 

 

 

 

 

 

 

RP 2C8

 

4

 

4

X120 B/C

 

B

B or C

 

 

 

 

 

 

 

 

 

 

4) no Fieldbus possibility (interface)

Caution!

The connections COM2 or COM3 B/C and X30 are implemented via SUB D09 socket. It is to be guaranteed by the customer that an interchanging is not possible!

The solder ring jumpers JP2.8, 2.3, 2.7, 2.2 must be switched dependent on the option module. See chapter 7.1 (factory-adjusted)

2.6.2.2Additional CAN-BUS2 Interface (Use in combination with other Fieldbus)

modul designation

 

interface

galvanic isolation

design

slot

RP 2CA

 

CAN2

X

C

C

 

 

 

 

 

 

RP 2C8

3)

CAN2

X

C

C

 

 

 

 

 

 

 

3)additional plug COM 3 (B)

________________________________________________________________________________________________________________________________________________________________________________________________________________________

36

Product Manual Type: 637f