Connector Assignments and Functions

2

 

 

 

 

 

 

 

 

 

Digital Interfaces

 

 

 

 

 

2.6.2.9 Pin assignment for Interbus S

 

 

 

 

 

with option module RP IBS, with galvanic isolation

 

 

Remote OUT (COM2)

 

 

 

 

 

 

Remote OUT (SUB D09 socket)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN

 

description

 

designation

 

 

 

 

 

 

 

 

 

 

Com 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Data line OUT forward

 

DO2

 

 

 

 

 

 

(error voltage A)

 

 

 

 

 

 

2

 

Data line IN backward

 

DI2

 

 

 

 

 

 

(error voltage A)

 

 

 

 

 

 

3

 

Reference potential

 

GND I

 

 

 

 

4

-

-

 

 

 

 

5

 

VCCI

 

+5V

 

 

 

 

6

 

Data line OUT forward

 

/DO2

 

 

 

 

 

 

(error voltage B)

 

 

 

 

 

 

7

 

Data line IN backward

 

/DI2

 

 

 

 

 

 

(error voltage B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

-

-

 

 

 

 

9

 

Reporting input *

 

RBST

 

 

 

* to forward Interbus-S interface

Remote IN (COM3 B) Remote IN (SUB D09 plug)

additional plug

PIN

 

 

Remote

description

designation

IN

 

 

1

Data line IN forward

DO1

 

(error voltage A)

 

2

Data line OUT backward

DI1

 

(error voltage A)

 

3

Reference potential

GND I

4

-

-

5

-

-

6

Data line IN forward

/DO1

 

(error voltage B)

 

7

Data line OUT backward

/DI1

 

(error voltage B)

 

8

-

-

9

-

-

Attention: specific front panel is required !

________________________________________________________________________________________________________________________________________________________________________________________________________________________

07-02-10-01-E-V0505.doc

Product Manaul Type: 637f

39