General Information | 1 |
|
|
Range Data
1.3.5Single- and
Due to the
The unloaded output voltage will be reduced to approx. 90%, maximally 85
%
only servo drive 637f / ..02 up to 06 see the following diagram:
Derating of servo drive output voltage in case of
Output current [ARMS]
12 |
|
|
|
|
|
|
10 |
|
|
|
|
|
|
8 |
|
|
|
|
|
|
6 |
|
|
|
|
|
|
4 |
|
|
|
|
|
|
2 |
|
|
|
|
|
|
0 | 0 | 20 | 40 | 60 | 80 | 100 [%] |
Output voltage in % of unloaded condition
Hint for parameterization:
To avoid unexpected tripping of the under voltage threshold, the parameter setting should be left on default values (EASYRIDER® Windows – Software).
Required
Approximation: (up to 3000RPM)
Ukl = 1,2 * (EMF * n / 1000) + I * (Rph + RL) [V]
Ukl | Required motor voltage [V RMS] |
EMF | |
Rph | Resistance of motor (between terminals) [Ω] |
RL | Line resistance of motor cable [Ω] |
I |
________________________________________________________________________________________________________________________________________________________________________________________________________________________
Product Manaul Type: 637f | 19 |