2

Connector Assignments and Functions

 

 

Digital Interfaces

2.6.2.12Pin assignment for I/O interface

with option module RP 2C8, with galvanic isolation

Digitale I/O Option

X120B orr X120C Cage – Clamp terminal 10pole..

(min./max. cable cross-section: 0,08mm² / 1,5mm²)

 

PIN

designation

 

comment

status

 

X120

 

Function 0

 

Function 1

 

 

 

 

 

 

 

 

 

 

1

Input 121

BIAS

 

Reset drive fault

Input

 

 

 

 

 

 

2

Input 122

BIAS

 

Limit switch +

Input

 

 

 

 

 

 

3

Input 123

BIAS

 

Limit switch -

Input

 

 

 

 

 

 

4

Input 124

BIAS

 

Reference switch

Input

 

 

 

 

 

 

5

Output 125

BIAS

 

Cam 1

Output

 

 

 

 

 

 

6

Output 126

BIAS

 

Cam 2

Output

 

 

 

 

 

 

7

Output 127

BIAS

 

Cam 3

Output

 

 

 

 

 

 

8

Output 128

BIAS

 

Cam 4

Output

 

 

 

 

 

9

+24 V SPS

Ext. +24 V feed-in

Ub

 

 

 

 

10

0 V SPS

Ground reference 0 V SPS

B

 

 

 

 

 

 

 

Signal statuses of the I/O are indicated in each case by a 2mm LED at the front plate.

Connector COM3 B – see chapter 2.6.2.6

LED lighten I/O = high

LED off I/O = low

X120

________________________________________________________________________________________________________________________________________________________________________________________________________________________

42

Product Manual Type: 637f

07-02-10-01-E-V0505.doc