Star Micronics NX-2415II user manual Set horizontal tab stops, Reset all tab stops, Horizontal tab

Models: NX-2415II

1 160
Download 160 pages 47.44 Kb
Page 97
Image 97
Set horizontal tab stops

I

Set horizontal tab stops

IModel

ASCII

I Decimal

I Hexadecimal

I

I Both I

<ESC> “D” ,,f 172 . <0>

I 27 68 rz/ ,,2...

0 I IB 44 rz/ ,,2 ..00

I

Cancels all current horizontal tab stops and sets new tab stops at columns nl, n2, etc. in the current character pitch (pica pitch if proportional spacing is currently selected), where nl, n2, etc. are numbers between 1 and 255. The maximum number of horizontal tab stops allowed is 32 in Standard mode and 28 in IBM mode. The tab stops must be specified in ascending order; any violation of ascending order terminates the tab stop list. Standard termination is by the <0> control code. To clear all tab stops, specify <ESC> “D”

<o>.

Reset all tab stops

Mode

ASCII

Decimal

Hexadecimal

IBM

<ESC> “R”

27 82

IB 52

Resets the horizontal tab stops to their power-up values according to which a tab stop is set every 8 colulmnsstarting at column 9. Also clears all vertical tab stops.

Horizontal tab

Mode

ASCII

Decimal

Hexadecimal

Both

<HT>

9

09

Moves the print position to the next horizontal tab stop. Ignored if there is no next horizontal tab stop in the current line. Note that when underlining is selected, spaces skipped by horizontal tabulation are not underlined.