Additionally, you may download the complete set of Intel Network Connections User Guides for your server’s network adapters at:

http://support.intel.com/support/network/sb/cs-009715.htm

Completing the IPMItool Installation

The IPMItool is a command line utility that reads the sensor data repository (SDR) and displays sensor values, System Event Log (SEL) entries, Field Replaceable Unit (FRU) inventory information, gets and sets LAN configuration parameters, and performs chassis power control operations via the server’s service processor. IPMItool is supplemental software and may be installed using the server’s Tools and Drivers CD or using the Installpack.exe executable file (described earlier in this chapter).

Once installed, the IPMItool may be used to access your server’s service processor (or another Sun server’s service processor) in the following ways:

Through the server’s ILOM (Integrated Lights Out Manager) interface. For details on using ILOM, refer to your server’s ILOM documentation.

Through the server’s Windows operating system. To use the IPMItool with Windows, it must be used in conjunction with the IPMI System Management driver (available with Windows Server 2003 R2 SP2). To make sure you have what you need to use the IPMItool with Windows Server 2003, refer to the requirements listed below.

Requirements

To use IPMItool, ensure that you have completed the requirements specified for your Windows Server 2003 version:

For Windows Server 2003 R2 SP2:

Install IPMItool as described in “To Install Supplemental Software” on page 51.

Install Microsoft’s IPMI System Management driver in Windows Server 2003 R2 SP2.

Configuration is required. Perform the steps described in “To Install Microsoft’s IPMI System Management Driver (Windows Server 2003 R2 SP2)” on page 57.

For Windows Server 2008:

Install IPMItool as described in “To Install Supplemental Software” on page 51.

No configuration is required. IPMItool is ready for use.

Chapter 8 Update the Critical Server-Specific Drivers

55

Page 63
Image 63
Sun Microsystems X6250 manual Completing the IPMItool Installation, For Windows Server 2003 R2 SP2