Chapter 5: Advanced Serverboard Setup

HDD LED

The HDD LED (for IDE and SCSI drives) connection is located on pins 13 and 14 of JF1. Attach the drive LED cable to these pins to display disk activity. See the table on the right for pin definitions.

NIC1/2 LEDs

The NIC (Network Interface Con- troller) LED connections for GLAN1 are located on pins 11 and 12 of JF1 and the NIC LED con- nections for GLAN2 are located on pins 9 and 10 of JF1. Attach the NIC cables to display network ac- tivity. Refer to the table on the right for pin definitions.

Overheat/Fan Fail LED

Connect an LED to the OH/Fan Fail connection on pins 7 and 8 of JF1 to provide warning of system overheating or system fan failure. The LED will flash/stay on as long as the fan fail/overheat condition exists. Refer to the table on the right for pin definitions and Chap- ter 3 for details.

Power & PWR Fail LED

The Power/Power Fail LED con- nection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions.

HDD LED

Pin Definitions

(JF1)

Pin

Number Definition

13Vcc

14HD Active

NIC LED

Pin Definitions

(JF1)

Pin

Number Definition

9/11 Vcc

10/12 GND

OH/Fan Fail LED

Pin Definitions

(JF1)

Pin

Number Definition

7Vcc

8GND

Power/Power Fail

LED Pin Definitions

(JF1)

Pin

Number Definition

5LED-

6LED+

5-15