Operating the Equipment Locally
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Enco d er Page 4-93
ST.TM.E10076.3
4.12.6 Bit-rate (188) and Bit-rate (204) Option
NOTE…
If the Packet Length option is set to 188 bytes then only the Bit-rate (188) option is displayed. If the
Packet Length option is set to 204 bytes then both the Bit-rate (188) and Bit-rate (204) options are
displayed.
To access the either of the bit-rates, press the Bit-rate (188) or the
Bit-rate (204) softkey in the Mux Menu.
Both the Bit-rate (188) and the Bit-rate (204) can be in the range of
0 Mbit/s to 50 Mbit/s.
Table 4.113: Bit-rate (188) and Bit-rate (204) Options
Selected Option Description
188 / 204
Min: 0.0000 Mbit/s
Max (without Remux):110.0000 Mbit/s
Max (with Remux): 50.0000 Mbit/s
Step Size: 0.0001 Mbit/s
Multiplexer output bit-rate when in baseband output
format and ASI output mode.
Changing the bit-rate affects the automatic video bit-
rate and video resolution calculations.
If the specified bit- rate is outside the valid input range, a con firmation
screen is displayed which shows the maximum/minimum value allowed.
4.12.7 Clock
NOTE…
This option indicates the origin of the clock. Prior to Build Version 3.0.0 it was set to Local Oscillator
and could not be changed. After Build Version 3.0.0 it must be set to a video or external source before
attempting to change the clock value or it will default to Local Oscillator.
To access the Clock option, press the Clock softkey in the Mux Menu.
Table 4.114: Clock Options
Selected Option Description
Local Oscillator The system clock is derived from the local oscillator.
HSYNC (External) The system clock is locked to the HSYNC input.
Video The system clock is locked to the video source.
4.12.8 PCR PID Option
To access the PCR PID option, press the PCR PID softkey in the Mux Menu.
This shows the Program Clock Reference Packet Identifier.
Table 4.115: PCR PID Options
Selected Option Description
Min: 1
Max: 8190 (1FFEh)
Step Size: 1