Installing the Equipment
Page 2-6 Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
ST.TM.E10076.3
The unit is designed for stationary or fixed use only. Ensure it is firmly and
safely located and has an adequate through-flow of air. Allow at least
50 mm free air-space at each side of the equipment. Units in racks can be
stacked without ventilation panels between. Racks containing stacked
equipment may need to be forced-air cooled to reduce the operating
ambient temperature. For stacking constraints contact Customer Services.
The 1U Encoder uses a similar air-flow path, with three fans on each side
of the unit. With both 1U and 2U units it is important not to block the front
air intake on the bottom-left corner of the front panel (see Figure 2.2).
Figure 2.2: Air Path Through the Enclosure
2
Warm air out
(right, front)
4
Warm air out
(left, rear)
1
Cool air in
(front – via bottom vent)
Do not block the air intake.
Two fans mounted
at front, right side
of unit
3
Cool air in
(right, rear)
Three fans mounted
at rear, left side of
unit