Operating the Equipment Locally
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Enco d er Page 4-121
ST.TM.E10076.3
4.17.5 Backup Configurations
Backup FLASH stores a copy of each of the 16 user configurations when
you select Store Con f igs in Backup, you will be as ked for the passwo rd
here.
If unsure of the user configurations or they become inadvertently modified,
the user configurations can be returned to a known state at any time by
the command Load Con fi gs from Backup. This loads the 16 ba ckup
configurations to t he User FLASH, ove rwriting all user config urations that
are not write-protected. Individual configurations cannot be selected for
loading to the User F LASH.
The active (current) configuration is unaltered when you select Load
Configs from Backup.
4.17.6 Factory Default Configurations
There are 16 default configurations for both 525 and 625 line standards.
They are provided as examples and can be used as they are, if their
settings suit your needs. They are non-editable. The 16 default
configurations (525 or 625) can be loaded to the user FLASH at any time
by selecting Factory 525 (or 625) Defaults. This will overwrite all user
configurations that are not write-protected. Individual configurations
cannot be selected for loading to the User FLASH.
4.17.7 Configuration, Write-Protection
Any or all of the 16 use r configurations ca n be write-protect ed by selecting
Write Protect Configs. A password is asked for. With the correct
password entered, the question Write protect Which Configs? appears.
Select which configu rations to protect by pressing the associated softkey in
each case. This toggles the write-protect condition (On or Off) for each
individual configuration . The letter R when shown to the left of the config
number, indicates that the configuration is read-only (write-protected).
Any configuration th at is write-protect ed will be displayed as re ad-only if
attempting to overwrite it.
4.17.8 Quick Configuration From the Summary Screen
The sixteen predefined user configurations are a quick and easy way to
configure the Encoder without having to enter individual parameters. The
Config Menu can be accessed directly from the summary screen (see
Section 4.4.2, Summary Screen) by pressing the Cfgs softkey. Press the
Load Active Config softkey (see Load Active Config Option on
page 4-122) and a list of configu rations is shown (re fer to Annex C,
Predefined User Configurations for details of individual co nfigurations).
Select the required one by pressing the associated softkey. Nothing more
need be done. The Encoder is ready for use.