Installing the Equipment
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Enco d er Page 2-21
ST.TM.E10076.3

IF Out 2

A 75 W BNC socket provides a 70 MHz IF output used for
monitoring.
Table 2.18: IF Out 2 Connector
Item Specification
Connector Type BNC 75 W Female
Type Analogue
Connector designation IF Out 2
Pin-outs Centre Signal
Screen Ground
2.7 Powering Up/Down

2.7.1 Before Powering Up

Before powering up the Encoder, check that:
1. The unit has been ins talled in a suitable loca tion.
2. The unit has been connected to external equipment and power supply,
as required.
3. The power supply has been checked and a good earth provided.
4. The correct fuse type and rating has been fitted to the equipment and,
for the ac supply version, the ac power cable.

2.7.2 Powering Up

To power up the Encoder:
1. Turn on the local power supply. The Encoder executes a series of
power-up initialisatio n and self-test rou tines.
2. Confirm that the green Power LED is lit and that the red Alarm LED is
unlit.
3. Ensure that the Stand-by switch is set to On (see Chapter 1,
Introduction, Figure 1.8).
After the boot period the Encoder Input Monitor screen is displayed.
NOTES…
1. The fans on the Encoder can be temperature controlled so may not be on if the ambient
temperature is low. Refer to Annex B, Technical Specification for more information.
2. During initialisation invalid PIDs may appear momentarily in the transport stream.

2.7.3 Powering Down

To power down the Encoder remove the power supply connection at the
rear of the unit.