Installing the Equipment
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Enco d er Page 2-15
ST.TM.E10076.3
Table 2.6: Audio In Connector
Pin Signal Pin Signal
Analogue Digital Analogue Digital
1 Left Channel A (+) AES/EBU (A) (+) 9 Left Channel A (-) AES/EBU (A) (-)
2 Not connected 10 Right Channel A (+)
3 Right Channel A (-) 11 Not connected
4 Left Channel B (+) AES/EBU (B) (+) 12 Left Channel B (-) AES/EBU (B) (-)
5 Not connected 13 Right Channel B (+)
6 Right Channel B (-) 14 Not connected
7 AES/EBU
Reference (Signal) 15 AES/EBU
Reference (Ground)
8 Not connected
NOTES…
1. In analogue mode termination is either 20 kW or 600 W.
2. In AES/EBU mode termination is 110 W.
3. When the Encoder is powered down the digital channel is selected with 110 W termination.
4. The digital audio input does not support SPDIF.
5. In order to comply with EMC regulations, use the audio break-out cable supplied with the unit.
2.6.7 ASI OUT 1, 2 and 3 Outputs
Connect the Multiple xer or Modulator A SI cable to the
appropriate ASI OUT connector, using good quality
75 W coaxial cable (for example, BBC PSF 1/3).
A 75 W BNC connector provides the output from the Encoder.
Table 2.7: ASI OUT 1, 2 and 3 Connectors
Pin Signal
Centre Signal
Screen Ground
2.6.8 Control Interfaces

Connection

Operation of the Encoder from a TANDBERG Television control system is
via the Ethernet network running the Simple Network Management
Protocol (SNMP) protocol. Connect the ETHERNET connector to the
controller (for exa mple, MEM). Local c ontrol is implemented through the
front panel keypad and display. See Chapter 4, Operating the Equipment
Locally for details of how to access the front panel menus.