Installing the Equipment
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Enco d er Page 2-17
ST.TM.E10076.3

Remote Control

A 9-way, D-type male connector provides an
RS-232/RS-485 port for remote control of the
Encoder (see Serial Protocol Option). This
connector is wired as a DTE.
Table 2.10: Remote Control Connector (RS-232/ RS-485)
Remote (DTE) Encoder (DTE) Remote Control
Signal Name Signal Direction Pin Signal Name
1 Not connected
Transmit Data 2 Received Data (RS-232)
Received Data 3 Transmi t Data (RS-232)
4 Not connected
Signal Ground 5 Signal Ground
Transmit Data B 6 Received Data B (RS-485)
Received Data A 7 Transmi t Data A (RS-485)
Received Data B 8 Transmi t Data B (RS-485)
Transmit Data A 9 Received Data A (RS-485)
NOTES…
1. Signal names are with respect to a DTE in accordance with the RS-232 and RS-485
specification. A is positive and B is negative.
2. A null modem connection must be used when connecting DTE together.
2.6.9 Data

RS-232 Connector

RS-232 data is available on the Base Board2 and the option module
M2/EOM2/DAT.
Table 2.11: RS-232 Data Connector (Base Board) - Asynchronous
Remote (DTE) Male Encoder RS-232 (DTE) Female
Signal Name Pin Signal Direction Pin Signal Name
1 1 Not connected
Received Data 2 2 Received Data
Transmit Data 3 3 Transmit Data
4 4 Not connected
Signal Ground 5 5 Signal Ground
6 6 Not connected
7 7 Not connected
8 8 Not connected
9 9 Not connected
2 RS-232 data is not supported on the Base Board before Build version 2.0.