TANDBERG Codec C90 and Profiles using C90 | Administrator guide |
ContentsContents
IntroductionIntroduction
AdvancedAdvancedAdvancedconfigurationconfigurationconfig.
PassPasswordord protectionprotection
AboutAboutmonitorsonitors
AudioAudiomattersat ers
AppendicesAppendices
ContactContactusus
The Experimental menu
The Advanced configurations menu has an option called Experimental. The settings within this menu can be used ‘as is’ and will not be further documented. NOTE! The Experimenal menu WILL change.
Experimental Audio Input Microphone [1..8] Channel
The Experimental settings can be used ‘as is’. NOTE: The Experimental settings WILL change. Defines whether the microphone signal is a mono signal or part of a multichannel signal.
Valuespace: <Left/Right/Mono>
Left: The microphone signal is the left channel of a stereo signal.
Right: The microphone signal is the right channel of a stereo signal.
Mono: The microphone signal is a mono signal.
Example: Experimental Audio Input Microphone 1 Channel: Mono
Experimental Audio Input Microphone [1..8] EchoControl HighPassFilter
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <On/Off>
Example: Experimental Audio Input Microphone 1 EchoControl HighPassFilter:
Off
The Experimantal menu, cont...
Experimental CustomSoftbuttons State [1..2] Softbutton [1..5] Type
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <NotSet/MainSource/PresentationSource/CameraPreset/Actions/SpeedDial>
Example: Experimental CustomSoftbuttons State 1 Softbutton 1 Type: NotSet
Experimental CustomSoftbuttons State [1..2] Softbutton [1..5] Value
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <S: 0, 255>
Example: Experimental CustomSoftbuttons State 1 Softbutton 1 Value: “”
Experimental SoftwareUpgrade Mode
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change..
Valuespace: <Auto/Manual>
Example: Experimental SoftwareUpgrade Mode: Auto
Experimental AudioTracking Camera [1..7] Mode
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <On/Off>
Example: Experimental AudioTracking Camera 1 Mode: Off
Experimental SoftwareUpgrade ServerAddress
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <S: 0, 255>
Example: Experimental SoftwareUpgrade ServerAddress: “http://csupdate. tandberg.com/getswlist.py”
Experimental CapsetFilter
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <S: 0, 32>
Example: Experimental CapsetFilter: “”
Experimental Conference [1..1] PacketLossResilience
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <On/Off>
Example: Experimental Conference 1 PacketLossResilience: Off
Experimental SystemUnit Controller Address
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <S: 0, 255>
Example: Experimental SystemUnit Controller Address: “”
Experimental UserInterfaces OSD PhonebookMerged
The Experimental settings can be used ‘as is’ and will not be further documented. NOTE: The Experimental settings WILL change.
Valuespace: <On/Off>
Example: Experimental UserInterfaces OSD PhonebookMerged: Off
36 | www.tandberg.com |