The Conference settings

Conference [1..1] AutoAnswer Delay

Defines how long (in seconds) an incoming call has to wait before it is answered automatically by the system. Requires the Autoanswer Mode to be enabled.

Valuespace: <0..50>

Range: 0-50 seconds

Example: Conference 1 AutoAnswer Delay: 0

Conference [1..1] AutoAnswer Mode

Set the Autoanswer mode.

Valuespace: <On/Off>

On: The system will automatically answer all incoming calls.

Off: All incoming call must be answered manually by pressing the OK key or the green Call key on the remote control.

Example: Conference 1 AutoAnswer Mode: Off

Conference [1..1] AutoAnswer Mute

The Autoanswer Mute setting determines whether the microphone is muted when an incoming call is automatically answered.

Valuespace: <On/Off>

On: The incoming call will be muted when automatically answered.

Off: The incoming call will not be muted.

Example: Conference 1 AutoAnswer Mute: Off

Conference [1..1] MicUnmuteOnDisconnect

The MicUnmuteOnDisconnect setting determines if the microphones should be automatically unmuted when all calls are disconnected. In a meeting room or other shared resource this could be done to prepare the system for the next user.

Valuespace: <On/Off>

On: Microphones will be unmuted when all calls are disconnected

Off: Microphones will not be unmuted when all calls are disconnected

Example: Conference 1 MicUnmuteOnDisconnect: On

The Conference settings, cont...

Conference [1..1] DoNotDisturb Mode

The Do Not Disturb setting determines whether or not there should be an alert on incoming calls.

Valuespace: <On/Off>

On: Set to On when you want no alert to incoming calls. The calling side will receive a busy signal when trying to call the codec.

Off: This is the default setting. The DoNotDisturb is automatically turned Off if the codec receives any IR signal from the handheld remote control.

Example: DoNotDisturb Mode: Off

Conference [1..1] IncomingMultisiteCall Mode

The Incoming Multisite Call setting determines whether or not the system should accept incoming calls to an already active conference.

Valuespace: <Allow/Deny>

Allow: When set to Allow, and with an ongoing MCU call/conference, the user can accept another incoming call. This will result in the incoming call being added to the MCU conference.

Deny: The system will not accept incoming calls when you are in a call. The calling side will receive a busy signal.

Example: Conference 1 IncomingMultisiteCall Mode: Allow

Conference [1..1] FarEndControl Mode

Lets you decide if the remote side (far end) should be allowed to select your video sources and control your local camera (pan, tilt, zoom).

Valuespace: <On/Off>

On: Set to On when you want the far end to be able to select your video sources and control your local camera (pan, tilt, zoom). You will still be able to control your camera and select your video sources as normal.

Off: When set to Off the far end can not access any of the features above on your system.

Example: Conference 1 FarEndControl Mode: On