3.4.2 Removal from and Insertion to the Fixed Slots

Operation 1 Remove the cartridges that are housed in the fixed slots (i.e., slot 8 to 10). (The cartridges will move to slot 5 to 7 within the magazine at this time.)

Operation 2 Reload a magazine into the main unit that has vacant slots for slot 5 to 7.

Operation 3 Lock the front door and wait for "READY" to be displayed.

Operation 4 Press the "ENTER" key.

Display: STATUS

Operation 5 Press the "arrow" key and select the EJECT command. Display: EJECT

Operation 6 Press the "ENTER" key and define the command.

Display: Eject Drv?

Operation 7 Press the "arrow" key and select "Eject Slot?" .

Display: Eject Slot?

Operation 8 Press the "ENTER" key and execute the command.

Display: Complete (when the command ends normally.)

Err. xxxxxx (when an error occurs. xxxxxx is the error code.)

Operation 9 When required, remove the magazine and remove the cartridges of slot 5 to 7 which have been moved.

Tip

Ejecting by command is valid only when slot numbers 5 to 7 among the magazine slots are all vacant slots.

When ejecting by command is executed, all cartridges housed in slot numbers 8 to 10 within the fixed slots are moved to the magazine.

- 20 -

Page 36
Image 36
Tandberg Data Tandberg LTO2 manual Removal from and Insertion to the Fixed Slots, Display Eject Slot?