- 29 -
Operation 6 Press the ENTER key and define the command.
Display; Lib.ID?
Operation 7 Press the arrow key and select "Drv. ID?" command.
Display: Drv. ID?
Operation 8 Press the ENTER key and define the command.
Display; Drv. ID 0?
Operation 9 Press the arrow key and select "Drv. ID 5" command.
Display: Drv. ID 5?
Operation 10 Press the ENTER key and define the command.
Display: Complete
Operation 11 Set the power switch of this device to OFF.
Operation 12 Switch the power of this device ON again.
Operation 13 Wait for the completion of the power-on test.
Display: "READY" and "DRV empty" are alternately displayed
Operation 14
Check the "READY" display and then switch on the power of the
server/workstation and the other devices to restart the system.
Important
When changing the SCSI ID of this device, be certain to execute a restart of
this device, the server/workstation, and any other devices. Note that the restart
of the server/workstation and the other devices should be executed after
checking the "READY" display of this device.