Teledyne API Model 200AU NOX Analyzer Instruction Manual, 02293, Rev. F

Table 5-13: RS-232 Command Summary

Commands

Definition

? [id]

Print help screen. ID is an optional instrument ID number.

 

 

T [id] LIST

Print all active test messages

 

 

T [id] LIST name or

Print single test message "name" from Table 5-16

T [id] name

 

W [id] LIST

Print all active warnings

 

 

W [id] CLEAR name or

Clear single warning message "name" from Table 5-17

W [id] name

 

 

 

C [id] command

Execute calibration "command" from Table 5-18

 

 

D [id] LIST

Prints all I/O signal values

 

 

D [id] name

Print single I/O signal value/state

 

 

D [id] name=value

Sets I/O signal to new "value"

 

 

D [id] LIST NAMES

Lists diagnostic test names

 

 

D [id] ENTER name

Enters and starts 'name' diagnostic test

 

 

D [id] EXIT

Exits diagnostic mode

 

 

D [id] RESET

Resets analyzer(same as power-on)

 

 

D [id] RESET RAM

System reset, plus erases RAM. Initializes DAS, NO, NOx, NO2 conc

 

readings, calib not affected.

 

 

D [id] RESET EEPROM

System reset, plus erases EEPROM (RESET RAM actions + setup

 

variables, calibration to default values). Restores all factory defaults.

D [id] PRINT

Prints properties for all data channels (DAS)

 

 

D [id] PRINT "name”

Prints properties for single data channel. Quotes around name are

 

required.

 

 

D [id] REPORT "name"

Prints DAS records for a data channel. Quotes around name are

[RECORDS=number]

required. Parameters in brackets are optional.

[COMPACTVERBOSE]

 

 

 

V [id] LIST

Print all setup variable names and values

 

 

V [id] name

Print individual setup variable value

 

 

V [id] name=value

Sets setup variable to new "value"

 

 

V [id] CONFIG

Print analyzer configuration

 

 

V [id] MODE

Print current analyzer mode

 

 

5-29

Page 67
Image 67
Teledyne 200AU instruction manual 13 RS-232 Command Summary, Commands Definition, Compactverbose

200AU specifications

The Teledyne 200AU is a cutting-edge analytical instrument designed primarily for trace and ultra-trace analysis of elements in various liquid samples. Renowned for its reliability and precision, this inductively coupled plasma mass spectrometer (ICP-MS) is widely utilized in environmental monitoring, food safety, clinical diagnostics, and geochemical research.

One of the distinguishing features of the Teledyne 200AU is its exceptional sensitivity, allowing for the detection of elements at concentrations as low as parts per trillion (ppt). This sensitivity is crucial for applications where even minute traces of contaminants can have significant implications. The instrument also boasts a wide dynamic range, accommodating high-concentration samples without compromising accuracy.

The Teledyne 200AU incorporates advanced technologies that enhance its analytical capabilities. At the core of its design is a robust ICP source, which ensures optimal ionization efficiency. The instrument also features a high-resolution quadrupole mass analyzer, which enables precise separation and identification of ions based on their mass-to-charge ratio. This feature is essential for distinguishing between isotopes and analyzing complex mixtures.

Another notable characteristic of the Teledyne 200AU is its user-friendly interface, which simplifies the operation and data management processes. The software is intuitive, offering sophisticated data processing algorithms that streamline analysis. Users can easily access real-time data visualization, facilitating timely decision-making based on analytical results.

The instrument is built with durability in mind, featuring a compact design that allows for easy integration into various laboratory environments. The Teledyne 200AU is also equipped with state-of-the-art safety features, including enhanced cooling systems and automated shutdown protocols to protect both the instrument and the user.

Moreover, the Teledyne 200AU supports a variety of sample introduction methods, including nebulization and laser ablation, providing flexibility to accommodate different types of samples and experimental needs. Its multi-element capability further enhances its versatility, allowing simultaneous detection of multiple elements in a single analysis.

In summary, the Teledyne 200AU stands out as a premier instrument in the field of mass spectrometry. Its combination of high sensitivity, advanced technology, user-friendly features, and robust design makes it an invaluable tool for scientists and researchers seeking precise elemental analysis across various disciplines.