| ValidatorTM How AutoTest Works |
Test Results Untitled1.job
| 2005 Aug 25 | |
100% | 10:53:01 | VALIDATOR |
Length
Max: 300ft
A184ft
B188ft
CShort 7 ft
D186ft
BERT Results:
Skew | SNR |
Max: 35ns | Min:20db |
--30.0
--30.0
--
--
BACKSPGUPC PG DOWN
Figure 4.4 Page Down to Display Distance To Short
Miswire - A wire or both wires of a pair are not connected to correct pins at the other end of the cable. For example, a reverse pair displays the wires connected to the correct pair of pins, but the two leads are reversed. (See Figure 4.5)
Test Results Untitled1.job
| 2005 Aug 25 | |
100% | 10:53:01 | VALIDATOR |
Cable001 |
| Remote ID: 1 | Fail |
| ||
|
| |||||
Test Time: 10:53 Thu 2005 Aug 25 | 1 Gbit/s |
| ||||
| Expected |
|
| Results | CAT5E |
|
1 |
| 1 | 1 |
| 1 |
|
2 |
| 2 | 2 |
| 2 |
|
|
| |||||
3 |
| 3 | 3 |
| 3 |
|
|
|
| ||||
6 |
| 6 | 6 |
| 6 |
|
|
|
| ||||
4 |
| 4 | 4 |
| 4 |
|
|
|
| ||||
5 |
| 5 | 5 |
| 5 |
|
|
|
| ||||
7 |
| 7 | 7 |
| 7 |
|
|
|
| ||||
8 |
| 8 | 8 |
| 8 |
|
|
|
|
|
|
|
|
BACKSPGUPC PG DOWN
Figure 4.5 Test Results-Miswire
Split Pair - The cable has an error in the twisting of the wires together within the cable. Cables are generally made up of 8 wires twisted together in 4 pairs. A cable can be wired with correct continuity, but not with correct pairing. If the only error is a split pair error, the cable has correct continuity. If the Validator main unit is unable to link to its remote due to another error, such as a short, A Link Test Error Message displays “Unable to Measure SNR.” Press OK to view the wiremap results. (See Figure 4.6)
56