4.6.Step by Step Instructions for Performing Auto Tests

Test-Um NT955 Series

ValidatorTM Running Manual Tests

4.6.Step by Step Instructions for Performing Auto Tests

1.From the Start Menu, navigate to the Job Manager using the arrow keys which move from left to right on each row.

2.Select the Job you wish to test. Press Open.

3.The Auto Test screen is presented with the Cable Test Schedule button highlighted. Press Select to view the Test Schedule. Press the up and down arrows to highlight the cable to be tested.

4.Using the appropriate cable assembly and jacks, connect the Validator-NT main unit to one end of the cable and the remote unit to the opposite end of the first cable identified in the Test Schedule.

Note: The Wiremapping Remotes (TP610) test wiremapping only and are NOT designed to work in the Auto Test mode. The Test Results will indicate Fail because the Validator was not able to perform a complete test sequence.

5.Press Test.

6.A message displays if the Main Unit is not communicating with the Remote Unit. If the Remote unit is not found, the main unit automatically sends tone on the cable. Using a Tone Tracer, such as Test-Um’s TT100, locate the cable you wish to test. Connect the Remote unit and testing will proceed.

7.Pass/Fail Test Results display, also indicating the speed the cable is certified to perform at, and whether the cable will support Voice over IP (VoIP).

8.The Validator-NT automatically increments to the next cable to be tested.

9.Testing will proceed through the entire Cable Test Schedule regardless of test failures.