17.13.1 Serial Port 0 Operation Mode 1 Example void show_baud_gen (void)

{

P3DDRL &= 0xf0;

P3DDRL = 0x07; //P30 input, P31 output

TF2 = CLEAR; T2 = CLEAR;

CKCON = 0x30; // Set timer 2 to clk/4

RCAP2 = 0xFF16; //37500 bps

THL2=0xFFFF;

/* Set T2 for Serial0 Tx baudgen.

Timer 2 is designated the clock source for the ”divide by 16” clock for the Transmit block, while Timer 1 is the implied source for the ”divide by 16” clock for the Receive block.

TR2 is activated*/

T2CON = 0x14;

//SCON: Async mode 1, 8−bit UART, enable rcvr; TI=CLEAR, RI = CLEAR SCON = 0x50;

PCON = 0x80; // Set SMOD0 for 16X baud rate clock //set Timer 1 up for Rx Baud Rate Generation @ 37500 bps TH1 = 0xF6;

/*Make the Timer 1 clocking Gated. This implies that for the Timer 1 to run, both TR1 and INT1# must be set.*/

TMOD = 0xA0;

TCON = 0x48;

//TI=SET;

}