13.2.3. Connections between the Remote controller and the Digital video recorder

[C-RF1000 Interface Unit Connections]

The maximum cable length is 1.2 km (3,937 ft) for each distance between the Remote Controller and the Interface Unit and between the Interface Unit and the farthest Digital Video Recorder.

The maximum cable length is 1.2 km (3,937 ft) for each distance between the Remote Controller and the Interface Unit.

 

Interface unit

 

C-RF1000

Remote controller 1

Screwless terminal

 

 

1

B

 

 

 

 

Remote controller 2

Screwless terminal

REMOTE CONTROLLER INPUT-

(Screwless terminal)

 

Remote controller 3

Screwless terminal

 

*1

 

Remote controller 4

Screwless terminal

432

*2

 

 

 

 

RS-232C

 

 

 

PC

 

 

Notes

*1. Match the transmission rate of all components connected to the Interface Unit. The Interface Unit's DIP switch settings must also be identical with the Remote Controller's bit rate settings.

*2. Remote Controller Input Terminal 4 cannot be used simultaneously with the RS-232C port. Connect either.

[Remote Controller connections using the dedicated cable]

The maximum cable length is 1.2 km (3,937 ft) for distance between the Remote Controller and the Digital Video Recorder of which termination switch is set to ON.

No AC adapter required

Termination switch: OFF

Termination switch: OFF

Termination switch: ON

 

Remote

 

 

Digital Video

 

 

Digital Video

 

 

Digital Video

 

 

Controller

 

 

Recorder

 

 

Recorder

 

 

Recorder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RJ-11

 

 

RJ-11

Screwless

Screwless

 

Screwless

Screwless

 

 

 

terminal

Power supply

terminal

terminal

terminal

 

terminal

terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supplied modular cable (3 m (9.8 ft))

CPEV-S larger than AWG22 (Ø0.65 mm)

Note: Do not connect the AC adapter.

55

Page 55
Image 55
TOA Electronics C-RM1000 CU operating instructions Remote Controller connections using the dedicated cable