7 CHECKING THE EQUIPMENT STATUS WITH TopAccess

Error Code

Problem Description

Corrective Action

 

 

 

 

Offramp security error

Confirm that the specified fax numbers are registered in the address

3C60-3C62

 

book of the equipment. If not, register the fax numbers in the address

 

book and ask the sender to resend the Email with the correct fax

 

 

 

 

numbers.

 

 

 

3C70

Power failure

Confirm that the job is recovered or not. If not, ask the sender to resend

 

the Email.

 

 

 

 

 

 

Destination address error

Ask your administrator whether the DNS and mail server settings are

3D10

 

correctly set. If they are correctly set, ask the sender to confirm that the

 

 

destination address is correct.

 

 

 

 

Exceeding maximum offramp destinations

Ask the sender to specify up to 40 destinations for one offramp gateway

3D20

 

job. The equipment cannot perform the offramp gateway transmission for

 

 

more than 40 destinations.

 

 

 

3D30

Fax unit is not installed

Make sure that the Fax unit is installed, or connected correctly.

 

 

 

 

POP3 server communication error

Ask your administrator whether the POP3 server address is correctly set,

3E10

 

and whether the POP3 server works properly. If SSL is enabled, make

 

 

sure that SSL port number is correctly set.

 

 

 

3E20

POP3 server communication timeout

Ask your administrator whether the POP3 server works properly and the

 

LAN cable is connected to the server.

 

 

 

 

 

3E30

POP3 login error

Ask your administrator whether the POP3 user name and password are

 

set correctly.

 

 

 

 

 

3E40

POP3 login type error

Ask your administrator whether the POP3 login type (Auto, POP3, APOP)

 

is set correctly.

 

 

 

 

 

3F00, 3F10,

File I/O error

Ask the sender to resend the Email. If the error still occurs, contact your

3F20, 3F30,

 

service representative.

3F40

 

 

114 Error Codes

Page 116
Image 116
Toshiba 455, 355, 305, 255, 205L manual 3D20