5. LOADING THE MEDIA

3.When performing a media calibration from your host computer, pull out the media through the Media Outlet, not through the Peel-off Unit. If a calibration is performed with the media set through the Peel-off Unit, multiple labels will be peeled at the same time, and stick on the printer. After the completion of the calibration, ensure that the distance between the media outlet and the leading edge of the media is 15 cm or over. If it is less than 15 cm, repeat the calibration until the distance becomes 15 cm or over. (Use this procedure particularly if the media length is short.)

15 cm or over

Precautions

When performing the “media calibration” from your host computer, ensure that the “peel” checkbox in the “Options” tab in the printer driver is unchecked.

If the “peel” checkbox is checked, peeling will fail. Consequently, the media calibration will not be performed successfully.

5- 6

Page 43
Image 43
Toshiba B-SX600 manual Precautions