Toshiba RAV-SM800AT-E, RAV-SM800UT-E 54, Item, Outline of specifications, Remarks, Notes

Models: RAV-SM800BT-E RAV-SM560BT-E RAV-SM560AT-E RAV-SM560UT-E RAV-SM800UT-E RAV-SM800AT-E

1 181
Download 181 pages 61.65 Kb
Page 54
Image 54
– 54 –

No.

Item

Outline of specifications

Remarks

9

Louver control

The louver angle is displayed

 

 

 

1) Louver

setting 0° as Full close.

Full close

 

 

 

 

 

 

position

 

 

 

 

 

1) In the initial operation after

 

 

 

 

0

 

 

 

power-ON, the position is

 

 

 

 

 

 

 

 

automatically controlled according to the operating

 

 

 

status (COOL/HEAT).

 

 

Cooling

Heating

45

103

2)After then a louver position is stored in the microcom- puter every time when position is operated on the remote controller, and the louver operates at the position stored in memory in the next operation and after.

*If the operation mode has been changed from COOL to HEAT, from HEAT to COOL, or the power has turned off, the stored louver position is cleared and the status returns to one in item 1).

 

2) Air direction

1) When pushing [LOUVER] button during operation, the

 

 

adjustment

louver starts swinging.

 

 

(Swing

2) When the louver has arrived at the desired position, push

 

 

operation)

 

 

[LOUVER] again. The louver stops at that position.

 

 

 

 

 

10 Frequency fixed

1) In case of wired remote controller

 

 

operation

1. When pushing [ON/OFF] button on the remote

[COOL]/[HEAT] flash.

 

(Test run)

controller continuously for 5 seconds, the mode

Air volume: [AUTO]

 

 

 

 

enters [TEST]. The indoor fan rotates with [HIGH]

Temperature

 

 

and a frequency fixed operation starts.

 

 

COOL: [L]

 

 

2. During this operation, the buttons other than [ON/

 

 

HEAT: [H]

 

 

OFF], [UP ] and [DOWN ] cannot be accepted.

 

 

However, items 7 and 8 are effective.

 

 

 

3. To stop the frequency fixed operation, use [ON/OFF]

Commanded frequency

 

 

button only.

Approximately [S7]

 

 

 

2)In case of wireless remote controller (Without wired remote controller)

1.When pushing [Temporary] button continuously for 10 seconds or more, Pisound is heard and the mode enters [TEST]. The indoor fan rotates with [HIGH] and a frequency fixed operation of [COOL] starts.

NOTES :

Temporary button is provided to near the display part of the main unit when opening the front panel.

If [Temporary] button is not continuously pushed for 10 seconds, Automatic heating/cooling operationis performed.

2. To stop the operation, push [Temporary] button again.

NOTE :

Operation on the wireless remote controller is not ac- cepted.