1. SPECIFICATIONS

1-1. Indoor Unit

1-1-1. 4-Way Air Discharge Cassette Type

Model name

 

 

 

 

 

RAV-SM560UT-E

RAV-SM800UT-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Heating

 

Average

Cooling

Heating

Average

Standard capacity (Note 1)

 

(kW)

 

 

 

 

 

 

 

 

 

5.3

 

5.6

 

 

7.1

8.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1.5 – 5.6)

 

(1.5 – 6.3)

 

 

(2.2 – 8.0)

(2.2–9.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating low temp. capacity (Note 1) (kW)

 

 

4.9

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

Energy consumption effect ratio (Cooling)

 

3.01 [B]

 

3.90 [A]

 

3.46

3.03 [B]

3.45 [B]

3.24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running current

 

(A)

8.42–7.72

 

6.78–6.29

 

 

11.32–10.37

11.22–10.28

 

Electrical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

1.76

 

1.435

 

 

2.34

2.32

 

characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Low temp.)

 

(kW)

1.89

 

 

2.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power factor

 

(%)

95

 

95

 

 

94

94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

 

 

 

 

Zinc hot dipping steel plate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

Ceiling Panel

 

Model

 

 

 

 

RBC-U21PG (W) E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Sold separately)

 

Panel color

 

 

 

Moon-white (Muncel 2.5GY 9.0/0.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

(mm)

 

 

 

256

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit

 

Width

(mm)

 

 

 

840

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outer

 

 

 

Depth

(mm)

 

 

 

840

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dimension

 

 

 

Height

(mm)

 

 

 

53

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

(mm)

 

 

 

950

 

 

 

 

(Sold separately)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

(mm)

 

 

 

950

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total weight

 

Main unit

 

(kg)

 

21

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling panel

 

 

 

 

 

4.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

 

 

 

Finned tubu

 

 

 

 

 

 

 

 

 

 

 

 

 

Soundproof/Heat-insulating material

 

 

Inflammable polyethylene foam

Foamed polyethylen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

Turbo fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan unit

 

Standard air flow High (Mid./Low)

(m³/h)

 

1050

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

(W)

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

 

Attached ceiling panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller (Sold separately)

 

 

 

 

 

 

RBC-AMT21E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side

 

(mm)

 

Ø12.7 (1/2”)

 

 

Ø15.9 (5/8”)

 

Connecting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid side

 

(mm)

 

Ø6.4 (1/4”)

 

 

Ø9.5 (3/8”)

 

pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain port

(Nominal dia.)

 

 

25 (Polyvinyl chloride tube)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound level

High (Mid./Low) (Note 2)

(dB•A)

32

 

29

 

27

34

31

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1 : The cooling capacities and electrical characteristics are measured under the conditions speciied by JIS B 8616 based on the reference piping. The reference piping consists of 3 m of main piping and 2 m of branch piping connected with 0 meter height.

Note 2 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.

Note : Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB