Toshiba RAV-SM560AT-E, RAV-SM800AT-E Indoor unit, Outdoor unit, 21, Indoor Unit/Outdoor Unit

Models: RAV-SM800BT-E RAV-SM560BT-E RAV-SM560AT-E RAV-SM560UT-E RAV-SM800UT-E RAV-SM800AT-E

1 181
Download 181 pages 61.65 Kb
Page 21
Image 21
– 21 –

Indoor Unit/Outdoor Unit

RAV-SM800UT-E, RAV-SM800BT-E, RAV-SM800KRT-E/RAV-SM800AT-E

Indoor unit

Air heat exchanger

TC sensor

Outer diameter of refrigerant pipe

Gas side ØA

Liquid side ØB

 

 

15.9mm

9.5mm

 

 

TCJ

sensor

 

 

Refrigerant pipe

 

Refrigerant pipe

 

 

 

 

at liquid side

 

at gas side

 

 

 

 

Outer dia. ØB

 

Outer dia. ØA

 

 

 

 

 

 

 

 

Max

 

 

 

 

 

 

 

 

 

 

 

 

50m

Pd

 

Packed valve

 

Packed valve

 

Ps

 

 

 

 

 

Outer dia. ØB

Outdoor unit

Outer dia. ØA

 

 

 

 

 

 

 

 

TS sensor

 

Strainer

 

Modulating (PMV)

 

 

 

 

(SKV-18D26)

 

 

 

 

 

 

 

 

 

 

TO sensor

 

 

 

 

TD sensor

Strainer

4-way valve

Accumulator

Muffler (STF-0213Z)

(1500cc)

Ø25 × L210

 

 

Ø25 × L160

 

Rotary compressor

 

(DA220A2F-20L)

TE sensor

Heat exchangerØ8 1 row 30 stages FP1.3 flat fin

Capillary Ø3×Ø2× L530

R410A 1.5 kg

Cooling

Heating

 

 

 

Pressure

 

Pipe surface temperature (°C)

Compressor

 

Indoor/Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor heat Outdoor heat

Indoor

temp. conditions

 

 

(MPa)

(kg/cm²G)

 

 

revolutions per

 

 

Discharge

Suction

(DB/WB) (°C)

 

 

 

 

 

 

 

 

exchanger

exchanger

second (rps)

fan

 

 

 

 

Pd

Ps

Pd

Ps

(TD)

(TS)

(TC)

(TE)

*

 

Indoor

Outdoor

 

Standard

3.3

0.9

33.4

8.8

86

11

9

44

64

HIGH

27/19

35/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Overload

3.7

1.1

37.8

11.4

90

21

18

54

52

HIGH

32/24

43/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low load

1.0

0.8

10.0

7.9

19

4

4

8

27

LOW

18/15.5

–5/–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

2.5

0.6

25.8

6.3

67

6

42

2

65

HIGH

20/–

7/6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

Overload

3.4

1.1

34.7

11.5

85

23

55

16

31

LOW

30.–

24/18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low load

2.0

0.2

20.3

2.3

89

–16

34

–18

90

HIGH

15/–

–20/(70%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*4 poles are provided to this compressor.

The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.

– 21 –

Page 21
Image 21
Toshiba RAV-SM560AT-E, RAV-SM800AT-E, RAV-SM800UT-E, RAV-SM560UT-E Indoor unit, Outdoor unit, 21, Indoor Unit/Outdoor Unit