Toshiba RAV-SM800BT-E, RAV-SM800AT-E 143, RAV-SM800UT-E, Cutting of Capillary Tube, Ref No

Models: RAV-SM800BT-E RAV-SM560BT-E RAV-SM560AT-E RAV-SM560UT-E RAV-SM800UT-E RAV-SM800AT-E

1 181
Download 181 pages 61.65 Kb
Page 143
Image 143
RAV-SM800UT-E

RAV-SM800UT-E

1. Cutting of Capillary Tube

 

 

 

A capillary tube (

025 026 : Inner diameter 2mm, Length 1000mm) is brazed to a distributor assembly.

Cut and divide the tube to each length as shown below.

 

 

 

 

 

 

 

 

 

 

Ref No.

 

No. of capillary tubes

 

Cutting

 

 

 

 

 

 

 

 

 

 

 

 

100 mm : 1 pc.

600 mm : 2 pcs.

 

 

025

 

7

300 mm : 1 pc.

700 mm : 1 pc.

 

 

 

 

 

400 mm : 1 pc.

800 mm : 1 pc.

 

 

 

 

 

 

 

 

 

 

 

 

100 mm : 2 pcs.

600 mm : 2 pcs.

 

 

026

 

10

150 mm : 1 pc.

900 mm : 1 pc.

 

 

 

 

 

500 mm : 4 pcs.

 

 

 

 

 

 

 

 

 

[Cutting]

Plane circumference of the capillary tube with triangle file, etc., and then break off it.

2.Attachment of joint pipe

Insert the attached joint pipe into the end of the capillary tube up to 15mm, and braze it.

Form the capillary tube as same as that in the distributor assembly before replacement.

NOTE) Break off the capillary tube so that inner diameter is not deformed

3.Brazing to indoor heat exchanger

Attach the capillary tube processed in items 1 and 2 to the end of the pipe with brazing as shown below.

025

026

143

Page 143
Image 143
Toshiba RAV-SM800BT-E, RAV-SM800AT-E 143, RAV-SM800UT-E, Cutting of Capillary Tube, Ref No, No. of capillary tubes