2 Theory of Operation (continued)

2.11 LCD Panel Control Circuit

Located at NH-SYS-M board (System MCU and Control Circuit)

 

 

TO LCD

 

 

 

 

Stand-Alone

 

 

CNM5

 

 

 

 

LED0

NORMALLED

 

VLED

1

2

VLED

 

 

 

 

 

LED1

BYPASS LED

 

LED0

3

4

LED1

 

 

 

LED2

5

6

LED3

 

 

LED2

FAULT LED

 

LED4

7

8

LED5

 

 

 

OFF

9

10

ENT

 

 

LED3

BATTERYLED

 

ESC

11

12

UP

 

 

 

DOWN

13

14

BKLIT

 

 

LED4

NC

 

NO+

15

16

G1

 

 

 

CONTRAST

17

18

LcdDATA

 

 

LED5

NC

LcdD0

LcdWR

19

20

LcdCS

LcdD1

(33)

 

21

22

 

 

 

(32) LcdD2

 

 

LcdD3

 

 

(34) LcdD4

 

23

24

 

LcdD5

(35)

 

 

(36)

 

25

26

 

LcdD7

(37)

 

RM116

(38) LcdD6

G1

27

28

G1

(39)

U-LcdDATA

 

29

30

 

(50)

LcdDATA

 

 

 

 

 

 

 

CM67

 

 

 

 

 

 

 

 

ZDM1

 

CM72CM73CM74CM75

G1

CM76CM77CM78CM79

 

 

 

 

 

 

 

 

 

 

RM126

KEY_ESC

 

KEY_ESC

ESC

 

 

 

CM85

 

(8)

 

RM127

 

G1

 

 

RM133

KEY DOWN

KEY DOWN

DOWN

 

 

 

 

 

(9)

 

 

 

 

G1

RM121

 

8

UM5

9

(49) U-LcdCS

LcdCS

G1

GND COM

CM80

ZDM2

 

 

 

(73)

U-LED0

7

7B

7C

10

LED0

 

 

 

 

U-LED1

6

11

 

 

 

 

(74)

U-LED2

5

6B

6C

12

LED1

 

 

G1

 

(75)

U-LED3

4

5B

5C

13

LED2

 

U-LcdWR

RM132

(76)

U-LED4

3

4B

4C

14

LED3

(63)

 

(77)

U-LED5

2

3B

3C

15

LED4

 

 

LcdWR

(78)

CENTRAL OK

1

2B

2C

16

LED5

 

CM90

 

 

(70)

 

 

1B

1C

 

BYP OK

 

 

ZDM3

 

 

 

 

 

 

 

 

 

 

CM91

RM135

+12VS

RM134

BKLIT

G1

 

G1

 

RM140

KEY OFF

KEY OFF

OFF

 

 

 

(22)

 

CM96

RM143

 

 

 

G1

 

RM147

KEY UP

KEY UP

UP

 

 

 

(10)

CM103 RM149

(62)

U-LcmBL RM137

RM139 QM9

RM144 G1

5VS

RM148

NO+

CM104

G1

RM138

+12VS

RM158

G1

 

CM121

CM118

EPO

(85)

HSM1

1

HS

UM10

1

 

 

VLED

Vin

+5V

3

 

 

GND2

CM120

 

CM119

 

G1

G1

RM152

KEY_ENT

KEY_ENT

 

 

 

ENT

 

 

 

 

 

CM110

RM154(7)

 

 

+12VS

 

 

 

 

4

 

 

 

 

 

2

 

G1

(2)

U-LcmCA

RM155

3

 

 

 

 

CM112

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

G1

G1

CM113

1

1CONTRAST

UM7A

LM324AD

G1

(a)MCU detects the status of EPO button (on LCD display panel) via “EPO” (85) (low active). When the EPO button is activated, UPS will shut down the output and turn off the inverter. When the EPO button is released, UPS will stay in bypass mode.

(b)MCU can control the LCD backlight via “U-lcmBL” (62).

(c)MCU can adjust the contrast of LCD by PWM control via “U-lcmCA” (2).

59

Page 41
Image 41
Tripp Lite SU60KX manual LCD Panel Control Circuit, To LCD