5 Troubleshooting (continued)

5.2 Troubleshooting Flow Charts (continued)

5.2.11 “BATTERY BAD”

Start

 

 

 

 

 

 

Is

 

N

 

 

 

the battery

 

Turn on battery

 

 

 

 

 

circuit breaker

 

 

 

circuit breaker

 

turned on?

 

 

 

 

 

 

Y

 

 

 

 

 

 

Is the external

 

N

 

Correct the wiring

 

wiring correct?

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

Fix the connection

 

 

 

 

 

 

 

 

 

 

 

 

N

Are the

N

 

 

Is the

Y

Is the Wire #31(1)

actual value

 

 

and LCD value the

 

LCD value zero?

 

connection OK?

same?

 

 

 

 

 

 

Y

 

 

 

N

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace P board or M

 

Check the fuse of

Battery broken

 

 

 

board (3)

 

external battery or

Replace battery

 

Calibrate parameter

 

internal battery

 

 

 

on EEPROM (2)

 

 

END

 

 

 

 

 

 

Fig 5.2.11a

Note (1): Wire #31 connects CNP10 on the NH-SYS-P board to CNB7 on the NH-SYS-B board (Figure 5.2.11b).

Note (2): To learn about EEPROM parameter settings and calibration, turn to section 3.2.

Note (3): For the location of the NH-SYS-P and/or NH-SYS-M board, turn to section 1.5. To replace the NHS-SYS-M board, remove the EEPROM chip from the old NHS-SYS-M board and insert it into the new one.

Fig 5.2.11b

107