Vulcan-Hart C24EA5 480V BASIC, C24EA5 480V PRO, C24EA3 208/240V PRO Condensate Thermostat

Models: C24EA5 208/240V BASIC C24EA3 480V BASIC C24EA5 208/240V PRO C24EA3 480V PRO C24EA3 208/240V BASIC C24EA3 208/240V PRO C24EA5 480V PRO C24EA5 480V BASIC

1 52
Download 52 pages 5.36 Kb
Page 16
Image 16
CONDENSATE THERMOSTAT

MODEL C24EA - THERMOSTATS

Installation

1.Insert capillary bulb through large compression nut.

A.Route capillary bulb through top of heating element.

B.Position capillary bulb between top of second and third heating element coils. Secure with hose clamp to second coil as shown.

2.Apply pipe thread sealant to threads of large capillary nut then install large compression nut.

A.Pull excess capillary tubing out of heating element through large nut. Route capillary tubing such that there are no sharp bends.

B.Tighten the small capillary compression nut into the large compression nut.

NOTE: Install a new gasket when reassembling steam generator tank. Temporarily secure gasket in place with RTV109.

3.Reinstall remaining parts removed in reverse order.

4.Torque heating element screws to 70 in*lb following the heating element tightening sequence as found under HEATING ELEMENT.

5.Check steamer for proper operation and leaks around heating element gasket and high-limit thermostat.

CONDENSATE THERMOSTAT

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Turn off machine to drain steam generator tank. Allow steamer to complete drain cycle.

A. Turn off water supply.

2.Remove LEFT SIDE PANEL as outlined in

COVERS AND PANELS.

3.Disconnect electrical wiring to condensate thermostat.

4.Remove condensate thermostat from drain box.

5.Reassemble parts removed in reverse order of removal. Make certain to apply Loctite 565 thread sealant to threads of thermostat before assembly.

6.Check steamer for proper operation and leaks around condensate thermostat.

F25213 (May 2006)

 

Page 16 of 52

 

Page 16
Image 16
Vulcan-Hart C24EA5 480V BASIC, C24EA5 480V PRO, C24EA3 208/240V PRO, C24EA3 208/240V BASIC Condensate Thermostat