Vulcan-Hart C24EA5 208/240V PRO Diagnostic Checks, Voltage, TOTAL kW, Current, Resistance Ohms

Models: C24EA5 208/240V BASIC C24EA3 480V BASIC C24EA5 208/240V PRO C24EA3 480V PRO C24EA3 208/240V BASIC C24EA3 208/240V PRO C24EA5 480V PRO C24EA5 480V BASIC

1 52
Download 52 pages 5.36 Kb
Page 21
Image 21
CURRENT

MODEL C24EA - SUPER HEATER

DIAGNOSTIC CHECKS

WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER AND FOLLOW LOCKOUT / TAGOUT PROCEDURES, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.

1.Check voltage across super heater wires at limiting and regulating contactor terminals.

A.If voltage is correct, check current draw (step 2).

B.If voltage is not correct, check the following:

1)Voltage supply to steamer.

2)Fuses or breaker open.

3)Relay K4.

4)Power to contactor coils.

5)Contactors not pulling in. (Mechanical)

2.Check current draw (amps) through super heater lead wires using an amp clamp meter.

A.If current is correct, then super heater is ok.

B.If current is not correct, check resistance (step 3).

3.Remove one of the super heater lead wires from the regulating contactor and check resistance using a VOM.

A.If resistance is not correct, replace super heater.

 

 

 

 

 

 

VOLTAGE

TOTAL kW

CURRENT

RESISTANCE (OHMS)

 

208/240

0.75

3.1

76.8

 

480Y/277 1

0.75

2.7

102.3

1Elements of 480V machines are connected in Wye configuration for 277V across super heater.

NOTE: Values in table are nominal. Tolerance is ±10 %.

4.Check steamer for proper operation.

Page 21 of 52

 

F25213 (May 2006)

 

Page 21