MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDS
SWITCHES, BUZZER AND SOLENOIDS
ON/OFF SWITCH
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
Basic Models
1.Pull out on handle to turn steamer off and drain generator tank.
2.Remove the RIGHT SIDE PANEL.
3.Locate the on/off switch assembly mounted to the manual drain valve.
4.Note wiring locations and disconnect electrical wiring from switch.
5.Remove switch from switch mounting bracket. Retain hardware.
6.Loosely install switch onto switch mounting bracket.
7.Perform Basic Model On/Off Switch - Adjustment as outlined in this section.
8.Connect electrical wiring to switch.
9.Check steamer for proper operation.
Basic Model On/Off Switch - Check Switch Actuation
NOTE: Handle must be pushed all the way in to avoid nuisance tripping.
1.Push handle in until switch contacts close. This can be checked with a meter set to measure resistance or continuity with meter probes across the COMMON and NORM OPEN terminals of switch.
2.Continue pushing handle in until handle is at physical stop.
A.If switch plunger
B.If contacts did not close, or, there was no
Basic Model On/Off Switch - Adjustment
1.Position switch mounting bracket on drain valve in middle of adjustment slot.
A. Tighten switch bracket to drain valve.
2.Loosen on/off switch mounting screws.
F25213 (May 2006) |