DOOR

MODEL C24EA - DOOR

DOOR

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.

REMOVAL

1.Close door.

2.Remove LEFT SIDE PANEL as outlined in

COVERS AND PANELS.

3.Remove nuts from upper hinge located inside front panel.

4.Open door slightly, and while holding door, pull upper hinge away from front panel.

5.Pull upper hinge out of upper door hinge bushing.

6.Lift door assembly up and off lower door hinge.

7.Reinstall parts removed in reverse order of removal.

8.Check door for fit and proper sealing of gasket.

GASKET

1.Open door.

2.Remove the shoulder screws and pan pusher bracket from gasket plate.

3.Remove gasket plate.

4.Remove gasket from inner door panel.

5.Remove RTV from bottom part of inner door panel. Apply new RTV 109 to bottom of door where shown when assembling gasket to door.

6.Place a small amount of RTV109 into the inner door panel gasket screw holes before assembly.

7.Position the new gasket on gasket plate and reverse procedure to install.

F25213 (May 2006)

 