MODEL C24EA - SUPER HEATER
SUPER HEATER
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.
REMOVAL AND REPLACEMENT
1.Turn off machine to drain steam generator tank. Allow steamer to complete drain cycle.
A. Turn off water supply.
2.Remove RIGHT SIDE PANEL as outlined under
COVERS AND PANELS.
3.Note super heater wiring connection points then disconnect heating element lead wires from the relay (K4) and the regulating contactor.
4.Peel back insulation from head of heater element.
5.Remove super heater element from insulated piping assembly.
NOTE: Top cover removed for clarity. Removal of top cover is not necessary to service super heater.
B.Tape insulation around head of heater element using
7.Check to make sure insulated piping assembly is horizontal or element head end of assembly is slightly elevated.
8.Check steamer for proper operation and leaks around super heater.
9.Reinstall panels and top cover.
6.Reassemble parts removed in reverse order of removal.
A.Apply pipe thread sealant to threads of super heater element before assembly.
F25213 (May 2006) |