![REFERENCE MATERIAL](/images/new-backgrounds/66130/661309x1.webp)
MODEL C24EA - GENERAL
Other chemical properties in water supplies can also affect good steam generation and vary from within each state and locality.
The water level probes in the steam generator tank use ions in the water to detect the water level. Do not use fully demineralized or
NOTE: The use of strainers, or filters will not remove minerals from the water.
Steamers that operate over a long period of time without the benefit of properly conditioned water, which have developed a heavy scale build up, should be cleaned before connecting to a conditioned water supply.
REFERENCE MATERIAL
For replacement parts, refer to Catalog of Replacement Parts
For operation, care and cleaning instructions, refer to Installation and Operation Manual
LUBRICATION
Component |
| Lubrication Type |
Heating Element |
| Never Seez |
Screws |
|
|
All NPT Fittings |
| Pipe Thread Sealant, Loctite |
|
| 565 |
Door Handle |
| Lubriplate 630AA |
Sliding Bracket |
|
|
|
| |
| TOOLS |
•Standard set of hand tools.
•VOM with A/C current tester (any quality VOM with a sensitivity of at least 20K ohms per volt can be used).
•Anti Static Kit, part no. TL - 84919.
•Pressure Gauge Assembly
•Low Pressure Gauge - 0 to 5 psi. recommended (Grainger Part No. 2C641).
•Water Hose Coupling - swivel type (Grainger Part No. 4KG87).
•Reducer Bushing (Grainger Part No. 6MN61).
•Pipe thread sealant (as required).
Special
•Torque Wrench - Capable of measuring 70 in*lb.
•Aluminum Foil Tape -
Page 5 of 52 |
| F25213 (May 2006) |
|