MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
NOTE: Perform a steam generator tank cleaning as outlined under STEAM GENERATOR TANK -
CLEANING.
DUAL WATER VALVE FLOW RATES
| Valve Type | Machine | Flow Rate (GPM) | |
| Fast Flow | Slow Flow | ||
|
| Type | Valve | Valve |
|
|
| ||
| Fill (Filtered | 3 & 5 Pan | 4.8 | 0.15 |
| Water) | |||
|
|
|
| |
| Condensate | 3 - Pan | 4.8 | 0.75 |
|
|
|
| |
| 5 - Pan | 4.8 | 1.35 | |
| Water) |
Filtered Water Solenoid Valve
1.Turn off machine to drain steam generator tank. Allow steamer to complete drain cycle.
A. Turn off water supply.
2.Disconnect the incoming filtered water hose to machine.
FILTERED AND NON-FILTERED
WATER SOLENOID VALVES
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
NOTE: The filtered and
3.Remove the REAR PANEL as outlined under
COVERS AND PANELS.
4.Remove the screws securing the solenoid valve to the back plate.
5.Pull solenoid valve toward right side of machine enough to access electrical connections.
A.Note connection points of electrical wires then disconnect wires from solenoid valve.
B.Disconnect hoses from solenoid valve then remove solenoid valve from steamer.
DUAL WATER VALVE
F25213 (May 2006) |
| Page 24 of 52 |
|