Vulcan-Hart C24EA5 480V PRO, C24EA5 480V BASIC, C24EA3 208/240V PRO, C24EA3 208/240V BASIC Buzzer

Models: C24EA5 208/240V BASIC C24EA3 480V BASIC C24EA5 208/240V PRO C24EA3 480V PRO C24EA3 208/240V BASIC C24EA3 208/240V PRO C24EA5 480V PRO C24EA5 480V BASIC

1 52
Download 52 pages 5.36 Kb
Page 33
Image 33
BUZZER

MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDS

A.Install valve with the inlet (ON) side of valve connected to the back panel port and the outlet (OFF) side of valve connected to the water level control plumbing. Apply liquid thread sealant to threads of piping before assembly.

7.Reassemble parts removed in reverse order. Perform DOOR LATCH ADJUSTMENT as outlined under DOOR.

BUZZER

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Remove the RIGHT SIDE PANEL.

2.Locate the buzzer which is mounted above the door switch near the front of steamer.

3.Disconnect electrical wiring from the buzzer and door switch.

4.Remove door striker.

5.Remove remaining hardware securing door switch mounting bracket to front panel then remove door switch mounting bracket, door switch and buzzer as an assembly.

6.Remove buzzer from door switch mounting bracket.

Page 33 of 52

 

F25213 (May 2006)

 

Page 33
Image 33
Vulcan-Hart C24EA5 480V PRO, C24EA5 480V BASIC, C24EA3 208/240V PRO, C24EA3 208/240V BASIC, C24EA3 480V PRO Buzzer