![BUZZER](/images/new-backgrounds/66130/6613065x1.webp)
MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDS
A.Install valve with the inlet (ON) side of valve connected to the back panel port and the outlet (OFF) side of valve connected to the water level control plumbing. Apply liquid thread sealant to threads of piping before assembly.
7.Reassemble parts removed in reverse order. Perform DOOR LATCH ADJUSTMENT as outlined under DOOR.
BUZZER
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.Remove the RIGHT SIDE PANEL.
2.Locate the buzzer which is mounted above the door switch near the front of steamer.
3.Disconnect electrical wiring from the buzzer and door switch.
4.Remove door striker.
5.Remove remaining hardware securing door switch mounting bracket to front panel then remove door switch mounting bracket, door switch and buzzer as an assembly.
6.Remove buzzer from door switch mounting bracket.
Page 33 of 52 |
| F25213 (May 2006) |
|