Vulcan-Hart C24EA5 480V PRO Manual Drain Valve Basic, Non-FilteredCold Water Solenoid Valve

Models: C24EA5 208/240V BASIC C24EA3 480V BASIC C24EA5 208/240V PRO C24EA3 480V PRO C24EA3 208/240V BASIC C24EA3 208/240V PRO C24EA5 480V PRO C24EA5 480V BASIC

1 52
Download 52 pages 5.36 Kb
Page 25
Image 25
Non-Filtered Cold Water Solenoid Valve

MODEL C24EA - WATER LEVEL CONTROL COMPONENTS

6.Reassemble parts removed in reverse order of removal.

7.Verify that the filtered water supply is connected to the input of the filtered water solenoid valve.

8.Check steamer for leaks and proper operation.

Non-Filtered Cold Water Solenoid Valve

1.Turn off machine to drain steam generator tank. Allow steamer to complete drain cycle.

A. Turn off water supply.

2.Disconnect incoming water hose to non-filtered cold water solenoid valve.

3.Remove LEFT SIDE PANEL as outlined in

COVERS AND PANELS.

4.Note connection points of electrical connections then disconnect wiring from solenoid valve.

VIEW FROM LEFT SIDE OF STEAMER

5.Remove the screws securing non-filtered cold water solenoid valve to back plate.

6.Note hose connections to solenoid valve then disconnect hoses from valve.

A.Remove solenoid valve from steamer.

7.Reassemble parts removed in reverse order of removal.

A.Connect the outputs of the non-filtered water cooling solenoid to the drain box and Tee mounted to the drain valve under the steam generator.

8.Verify that the non-filtered water supply is connected to the input of the non-filtered water solenoid valve.

9.Check steamer for leaks and proper operation.

MANUAL DRAIN VALVE (BASIC)

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

Removal

1.Pull out handle to turn off machine and drain steam generator tank. Allow steamer to complete drain cycle.

A. Turn off water supply.

2.Remove the RIGHT SIDE PANEL as outlined in COVERS AND PANELS. Rear panel can also be removed for added accessibility.

3.Remove the pin and disconnect the handle linkage from linkage bracket.

4.Remove the on/off switch and bracket as an assembly.

5.Disconnect the drain and drain flush hoses from the Tee located below the drain valve.

6.Remove the drain valve from the steam generator tank.

Page 25 of 52

 

F25213 (May 2006)

 

Page 25
Image 25
Vulcan-Hart C24EA5 480V PRO, C24EA5 480V BASIC Manual Drain Valve Basic, Non-FilteredCold Water Solenoid Valve, Removal