![Non-Filtered Cold Water Solenoid Valve](/images/new-backgrounds/66130/6613049x1.webp)
MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
6.Reassemble parts removed in reverse order of removal.
7.Verify that the filtered water supply is connected to the input of the filtered water solenoid valve.
8.Check steamer for leaks and proper operation.
Non-Filtered Cold Water Solenoid Valve
1.Turn off machine to drain steam generator tank. Allow steamer to complete drain cycle.
A. Turn off water supply.
2.Disconnect incoming water hose to
3.Remove LEFT SIDE PANEL as outlined in
COVERS AND PANELS.
4.Note connection points of electrical connections then disconnect wiring from solenoid valve.
VIEW FROM LEFT SIDE OF STEAMER
5.Remove the screws securing
6.Note hose connections to solenoid valve then disconnect hoses from valve.
A.Remove solenoid valve from steamer.
7.Reassemble parts removed in reverse order of removal.
A.Connect the outputs of the
8.Verify that the
9.Check steamer for leaks and proper operation.
MANUAL DRAIN VALVE (BASIC)
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
Removal
1.Pull out handle to turn off machine and drain steam generator tank. Allow steamer to complete drain cycle.
A. Turn off water supply.
2.Remove the RIGHT SIDE PANEL as outlined in COVERS AND PANELS. Rear panel can also be removed for added accessibility.
3.Remove the pin and disconnect the handle linkage from linkage bracket.
4.Remove the on/off switch and bracket as an assembly.
5.Disconnect the drain and drain flush hoses from the Tee located below the drain valve.
6.Remove the drain valve from the steam generator tank.
Page 25 of 52 |