MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
5.Disconnect the drain and drain flush hoses from the Tee located below the drain valve.
6.Remove the drain valve body from the steam generator tank.
7.Separate the Tee and nipple from the drain valve body.
8.Reassemble parts removed in reverse order. Apply liquid pipe thread sealant to threads of plumbing connections.
NOTE: If motorized drain valve is in the open position when power is applied to the steamer with the power switch on, drain valve will not close and fill water will flow through the generator into the drain.
9.Verify On/Off switch is in the off position and the motorized drain valve is closed before applying power to steamer.
NOTE: When power is applied and power switch is off steamer will enter a drain cycle.
10.Check steamer for proper operation and leaks around drain valve.
Page 27 of 52 |