Vulcan-Hart C24EA3 208/240V BASIC MODEL C24EA - WATER LEVEL CONTROL COMPONENTS, Page 27 of

Models: C24EA5 208/240V BASIC C24EA3 480V BASIC C24EA5 208/240V PRO C24EA3 480V PRO C24EA3 208/240V BASIC C24EA3 208/240V PRO C24EA5 480V PRO C24EA5 480V BASIC

1 52
Download 52 pages 5.36 Kb
Page 27
Image 27
Page 27 of 52

MODEL C24EA - WATER LEVEL CONTROL COMPONENTS

5.Disconnect the drain and drain flush hoses from the Tee located below the drain valve.

6.Remove the drain valve body from the steam generator tank.

7.Separate the Tee and nipple from the drain valve body.

8.Reassemble parts removed in reverse order. Apply liquid pipe thread sealant to threads of plumbing connections.

NOTE: If motorized drain valve is in the open position when power is applied to the steamer with the power switch on, drain valve will not close and fill water will flow through the generator into the drain.

9.Verify On/Off switch is in the off position and the motorized drain valve is closed before applying power to steamer.

NOTE: When power is applied and power switch is off steamer will enter a drain cycle.

10.Check steamer for proper operation and leaks around drain valve.

Page 27 of 52

 

F25213 (May 2006)

 

Page 27
Image 27
Vulcan-Hart C24EA3 208/240V BASIC, C24EA5 480V BASIC MODEL C24EA - WATER LEVEL CONTROL COMPONENTS, Page 27 of, F25213 May