Xantech mrc88 Dynamic Zone Link Programming, Zones 1,2,3 & 4 programmed for Dynamic Linking

Models: mrc88

1 102
Download 102 pages 7.92 Kb
Page 68
Image 68
Figure 37 – Dynamic Zone Link Programming

Page: 68

Model MRC88

NOTE: After the project has been transferred to the MRC88 Controller, the Zones will be permanently linked unless reprogrammed to be otherwise. All linked zones will have a small ‘L’ in the right side of the Volume Bar located in the LCD display on the keypad(s) in those zones. Simultaneously pressing the “STATUS” and “CH+” buttons will change the keypad display and indicate linked zones with a ‘highlight’ of the linked zone numbers. Zone 1 thru 4 Status will be displayed immediately upon entering Zone Link mode. Press the STATUS button again to view Zone Linking to Zones 5 thru 8. The display will ‘time out’ and return to the normal screen after 10 seconds of inactivity.

Figure 37 – Dynamic Zone Link Programming

Zones 1,2,3 & 4 programmed for Dynamic Linking

DYNAMIC ZONE LINK MODE (Factory default: “DISABLED”)

This mode allows zone linking ‘on the fly’. There may be times when it may be desirable to link multiple zones on a temporary basis (i.e. Linking the entire downstairs zones during a party.) Authorizing zones for ‘Dynamic Zone Linking’ is the same as programming ‘Static Zone Linking’ except once a zone has been authorized to link with another zone(s), the actual linking is implemented from Keypad button presses and can be reversed in the same way.

1.Select the Zone Linking tab in the MRC88 System Window

2.Locate a ROW of one of the Zones to allow Dynamic Linking.

3.Select a box in that row under the column number of the zone to link to. An Zones 1,2,3 & 4 programmed for Dynamic Linking will appear in the box selected.

4.Click on the same box again. A green Manual background will appear in the box indicating the Zones are in Dynamic Link Mode and may be dynamically linked and unlinked as desired after the project is transferred to the MRC88 Controller.

5.Repeat for all zones to be programmed for Dynamic Linking.

© 2003 Xantech Corporation

Page 68
Image 68
Xantech mrc88 installation instructions Dynamic Zone Link Programming, Zones 1,2,3 & 4 programmed for Dynamic Linking