Xantech mrc88 RS232 AND EXPANSION PIN OUT INFORMATION, Problem, Probable Cause And Solution

Models: mrc88

1 102
Download 102 pages 7.92 Kb
Page 97
Image 97
RS232 AND EXPANSION PIN OUT INFORMATION

Model MRC88Page: 97

 

PROBLEM

PROBABLE CAUSE AND SOLUTION

 

 

 

 

 

 

Problems Controlling the MRC88 via the RS232 port on

1.

Check the cabling between the controlling unit

 

the rear of the system.

 

and the MRC88.

 

 

2.

Verify proper command is being sent to the

 

 

 

MRC88. Refer to Appendix A and section on

 

 

 

RS232 Translator for recognized ASCII

 

 

 

commands.

 

 

3.

Verify RS232 Port settings are set properly for

 

 

 

both devices (i.e. Baud Rate, Data Bits, Stop

 

 

 

Bit etc..)

 

 

4.

Verify pin out from controlling device and the

 

 

 

MRC88 to be sure proper handshaking

 

 

 

between the Tx and Rx lines exist.

 

 

NOTE: Tx and Rx lines on the MRC88 are

 

 

reversed from a standard PC. This allows

 

 

communication between the MRC88 and a

 

 

standard PC Com Port without a Null Modem

 

 

cable.

 

 

 

 

 

 

Problems controlling an External Device via the MRC88

1.

Check the cabling between the controlling unit

 

rear Com Port

 

and the MRC88.

 

 

2.

Verify RS232 Port settings are set properly for

 

 

 

both devices (i.e. Baud Rate, Data Bits, Stop

 

 

 

Bit etc..)

 

 

3.

Verify pin out from controlling device and the

 

 

 

MRC88 to be sure proper handshaking

 

 

 

between the Tx and Rx lines exist.

 

 

 

NOTE: Tx and Rx lines on the MRC88 are

 

 

 

reversed from a standard PC. This allows

 

 

 

communication between the MRC88 and a

 

 

 

standard PC Com Port without a Null Modem

 

 

 

cable.

 

 

4.

Verify the MRC88 is sending the appropriate

 

 

 

commands out of the rear RS232 Port. This

 

 

 

can be done by connecting the rear RS232

 

 

 

Port directly to a PC’s Com Port running

 

 

 

Hyperterminal. View the command in

 

 

 

Hyperterminal to see if the exact commands is

 

 

 

being output correctly.

 

 

5.

Check the manufactures manual for the

 

 

 

correct ASCII/Hex commands.

 

 

 

NOTE: Sometimes a Carriage Return (0D

 

 

 

Hex) and even possibly a Line Feed (0A) is

 

 

 

required as terminating characters.

 

 

 

 

 

 

 

 

 

 