Rack Mount Frame Assembly and Installation

Three Phase Operation

Overview

XDI inverters can be configured for 3-phase operation where necessary. Synchronizing signals are used to achieve this functionality, precisely phase locking the units at 120 phase displacement. For single units this results in a 6kVA 3-phase source but up to 2 more units can be added to each phase to increase capacity. (See “Parallel Operation” on page 2–15 for wiring details.) The units can be configured for 3-phase, 4-wire or 3- phase,3-wire depending on the load setup.

Table 2-33-Phase Configurations

Wiring

 

 

 

 

 

Output

 

 

Configuration

Circuit

 

 

 

 

Terminals

Model Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 V

230 V

3-phase, 3-wire

 

 

 

 

L 1

Line/Phase

120

230

(DELTA)

 

 

 

 

Voltage

 

 

 

 

 

 

L 2

 

 

 

 

 

 

 

 

 

 

L 3

G N D

3-phase, 3-wire (Y)

L1

Line Voltage

208

230

 

 

 

L2

L3

G ND

3-phase, 4-wire (Y)

L1

Phase Voltage

120

230

 

N

 

 

 

 

 

Line Voltage

208

398

 

L2

 

 

 

L3

GND