Specifications
Inverter Specifications
Electrical Specifications
Input Voltage, Current, Power, Frequency Ranges
Nominal Input | - 48 VDC |
Input Range | - 40 to - 60 V (meets all specification) |
|
|
Safe Input Range | ± 80 Vdc (will not damage unit) |
|
|
Maximum Input Current | 90 A (at 40 V in, max 3 kW surge output, |
| 5 s max) |
|
|
Nominal input Current | 36 A (at 48 V input, 1500 W output) |
|
|
Maximum Input Current Ripple | < 1% Input Current |
|
|
DC Side Voice Band Noise Limit | less than 32 dBrnc |
| weighting) |
|
|
Over Current Protection | electronic limit on input boost converter |
| stage, 60 A fuse on DC input Inverter |
| stage output fuse for extreme faults |
|
|
Inrush Current Controlled | 40 A typical at 48 V < (2x Irated) |
Output Voltage, Current, Power, Frequency Ranges
Waveform | True Sinusoidal |
THD | < 3% Typical for linear loads |
|
|
Output Voltage | 120 Vac/60 Hz |
| 230 Vac/50 Hz |
|
|
Voltage Regulation | < |
|
|
Frequency Stability | ± 0.05% |
|
|
Frequency Accuracy | 60/50 Hz ± 0.1% |
|
|
Fully Isolated | input to output |
|
|
Power Rating | 2 kVA/1.5 kW Max, over full operating |
| temperature range |
|
|
Peak Output Current Into | 50Apk maximum for 120VAC |
Nonlinear Load | 25Apk maximum for 230VAC |
|