Table 6-11. Printer specifications and power requirements (Continued)

Printer requirements and specifications

Table 6-11. Printer specifications and power requirements (Continued)

 

Dimensions (width,

Total

 

 

Device

depth, height)

Weight

Heat dissipation

Power requirements

 

 

 

 

 

Printer with

W=183.5 in / 466.1

3,109 lbs /

DP 135:

60 Hz:

inverter

cm

1,411.9 kg

Operating:

DP 135:

feeder/stacker

H=59.6. in / 151.3 cm

 

28,140 BTU per hr

120/240 VAC or

and two

D=38.8 in / 98.6 cm

 

Standby:

120/208 VAC;

feeder/

 

 

4,454 BTU per hr

50 amp service;

stackers

Total space required

 

Energy Saver:

NEMA 14-50R,

 

(+ access):

 

2,700 BTU per hr

KVA 8.1(operating)

 

256.5 in W by 114 in

 

 

 

 

D /

 

DP 155 and 180:

DP 155 and 180:

 

648.9 cm W by 290.3

 

Operating:

120/208 VAC

 

cm D

 

32,770 BTU per hr

(182 V to 220 V),

 

 

 

Standby:

KVA 8.1(operating)

 

 

 

4,454 BTU per hr

 

 

 

 

Energy Saver:

Cord 1: 50 amp,

 

 

 

2,700 BTU per hr

NEMA 14-50R

 

 

 

 

Cord 2: 30 amp,

 

 

 

 

NEMA 14-30R

 

 

 

 

50 Hz:

 

 

 

 

Consult your local

 

 

 

 

service representative

 

 

 

 

 

Printer with

W=216 in / 730.8 cm

3,630 lbs /

DP 135:

60 Hz:

inverter

H=59.6 in / 151.3 cm

1,648.9 kg

Operating:

DP 135:

feeder/stacker

D=38.8 in / 98.6 cm

 

28,140 BTU per hr

120/240 VAC or

and three

 

 

Standby:

120/208 VAC;

feeder/

Total space required

 

4,454 BTU per hr

50 amp service;

stackers

(+ access):

 

Energy Saver:

NEMA 14-50R,

 

288 in W by 114 in D /

 

2,700 BTU per hr

KVA 8.1(operating)

 

730.8 cm W by 290.3

 

 

 

 

cm D

 

DP 155 and 180:

DP 155 and 180:

 

 

 

Operating:

120/208 VAC

 

 

 

32,770 BTU per hr

(182 V to 220 V),

 

 

 

Standby:

KVA 8.1(operating)

 

 

 

4,454 BTU per hr

 

 

 

 

Energy Saver:

Cord 1: 50 amp,

 

 

 

2,700 BTU per hr

NEMA 14-50R

 

 

 

 

Cord 2: 30 amp,

 

 

 

 

NEMA 14-30R

 

 

 

 

50 Hz:

 

 

 

 

Consult your local

 

 

 

 

service representative

 

 

 

 

 

Bypass

W=20.4 in / 51.9 cm

176 lbs /

---

---

transport

H=56.1 in / 142.5 cm

80 kg

 

 

 

D=28.3 in / 71.9 cm

 

 

 

 

 

 

 

 

6-26

Installation Planning Guide

Page 90
Image 90
Xerox 135, 100 Printer requirements and specifications, 11. Printer specifications and power requirements Continued, 6-26