66Operations

Adjust Media Sensors

Adjust Media Sensors

This section describes how to adjust the media sensors.

Black Mark Sensor

The optional black mark sensor is in a fixed position and is enabled via the control panel (see Set the Sensor Type on page 81 for details).

Transmissive Sensor

The transmissive sensor, which is used to detect web media, consists of two sections: a light source (the lower media sensor) and a light sensor (the upper media sensor). The media passes between the two.

Adjust these sensors only when the printer cannot detect the top of the label. The control panel LCD displays ERROR CONDITION PAPER OUT, even though there are labels loaded in the printer.

Upper Media Sensor

The upper media sensor must be positioned:

Directly over the hole or notch, or

Anywhere along the width of the media if there is a gap between labels.

Note • If you are using continuous media, position the upper media sensor over the media with the lower media sensor directly below it so that the printer can detect an out-of-paper condition.

To adjust the upper and lower media sensors, complete these steps:

1.Remove media and ribbon.

2.Locate the upper media sensor (1). The upper media sensor “eye” is directly below the adjustment screw head.

1

11342L-001 Rev. A

105SL User Guide

6/30/06