88Configuration
Control Panel Parameters
|
| Table 9 • Printer Parameters (Page 10 of 19) | |
|
|
|
|
| Parameter |
| Action/Explanation |
|
|
|
|
|
|
| Calibrate Media and Ribbon Sensor Sensitivity |
| MEDIA AND RIBBON |
| |
|
| Use this procedure to adjust sensitivity of media and ribbon sensors. | |
| CALIBRATE |
| Important • Follow this procedure exactly as presented. All of the |
|
|
| steps must be performed even if only one of the sensors requires |
|
|
| adjustment. You may press MINUS |
|
|
| to cancel the process. |
|
|
| To perform a media and ribbon sensor calibration: |
1.Press PLUS (+) to start the calibration procedure. The LOAD BACKING prompt displays.
2.Open the printhead.3.Remove approximately 8 in. (203 mm) of labels from the backing, and pull the media into the printer so that only the backing is between the media sensors.
4.Leave the printhead open.5.Press PLUS (+) to continue.The REMOVE RIBBON prompt displays.6.Remove the ribbon (if used).7.Close the printhead.8.Press PLUS (+) to continue.The message CALIBRATING PLEASE WAIT displays.The printer adjusts the scale (gain) of the signals that it receives from the media and ribbon sensors based on the specific media and ribbon combination being used. On the sensor profile, this essentially corresponds to moving the peak of the graph up or down to optimize the readings for your application.
When calibration is complete, RELOAD ALL displays.9.Open the printhead and pull the media forward until a label is positioned under the media sensor.
10.Reload the ribbon (if used).11.Close the printhead.12.Press PLUS (+) to continue.The printer performs an